Every cleanroom requires periodic testing to make sure it reaches the necessary particle count allowances for its cleanroom classification. A cleanroom is initially certified once it’s built, and then needs to be retested every 6 to 12 months to ensure it continues to comply with stringent requirements for cleanliness and control. Let’s go over what your cleanroom needs to test its cleanroom classification and how you can test your cleanroom yourself using a particle counter.
Document ISO 14644-2, Cleanroom Testing and Compliance, stipulates that all cleanrooms regardless of classification level must be routinely tested for quality. Particle count tests must be performed annually for cleanrooms ISO Class 6 and above, or biannually for ISO Class 5 and below.
Other recommended tests for cleanrooms include:
All cleanrooms have different levels of cleanliness they must reach, as outlined in their cleanroom classification. Careful monitoring and adherence to particle counts helps to maintain cleanliness and quality across ISO cleanroom classifications.
Here are the accepted levels of particles in each ISO class, designated by number and size:
ISO 14644-1 Cleanroom Standards | |||||
Class | Maximum Allowed Particles (per m3) | ||||
≥0.2 µm | ≥0.3 µm | ≥0.5 µm | ≥1 µm | ≥5 µm | |
ISO 1 | 2.37 | 1.02 | 0.35 | 0.083 | 0.0029 |
ISO 2 | 23.7 | 10.2 | 3.5 | 0.83 | 0.029 |
ISO 3 | 237 | 102 | 35 | 8.3 | 0.29 |
ISO 4 | 2,370 | 1,020 | 352 | 83 | 2.9 |
ISO 5 | 23,700 | 10,200 | 3,520 | 832 | 29 |
ISO 6 | 237,000 | 102,000 | 35,200 | 8,320 | 293 |
ISO 7 | 2.37×106 | 1,020,000 | 352,000 | 83,200 | 2,930 |
ISO 8 | 2.37×107 | 1.02×107 | 3,520,000 | 832,000 | 29,300 |
ISO 9 | 2.37×108 | 1.02×108 | 35,200,000 | 8,320,000 | 293,000 |
Whether your cleanroom requires formal testing every 6 or 12 months, it’s important to know how to test the particle count in your cleanroom to make sure you are reaching the levels set by your cleanroom classification. Let’s go through the steps of how to test your cleanroom classification using a particle counter.
Your cleanroom requires periodic testing to make sure it reaches the necessary particle count allowances and is effectively maintaining a clean, controlled environment. If you’re concerned that your cleanroom is not reaching the required particle count for your ISO class, talk to the cleanroom experts at Angstrom Technology today. We design, build, and install high-quality cleanrooms that can reach and maintain any cleanroom classification, and would be happy to professionally assess yours and help you meet your standards.
Cleanrooms are designed to prevent contamination and protect sensitive products. But even with the best…
Maintaining a controlled environment is critical when manufacturing medical devices. Cleanrooms play a pivotal role…
Proper cleanroom maintenance helps prevent contamination and extends the lifespan of the cleanroom and its…